SINCR C10 Series Mini frequency inverter, its high-performance current vector control technology enables asynchronous motor control, its capacity is 0.4kW ~ 2.2kW.
1. Carrying 485 communications port.
2. Built-in PID can achieve up to 16-steps speed running.
3. It is with pendulum frequency and fixed length control, and can be used in the textile, paper, drawing, machine tools, packaging, food, fans, pumps and other automatic control applications.
Specifications
Control characteristics | Control method | Closed loop vector control | Open loop vector control | V/F control |
Starting torque | ---- | 0.5Hz 150% | 1.5Hz 150% |
Speed range | ---- | 1:100 | 1:50 |
Steady speed accuracy | ---- | ± 0.2% | ± 0.5% |
Torque control | ---- | With | No |
Torque accuracy | ---- | ± 10% | ---- |
Torque response time | ---- | <20ms | ---- |
Product Features | Key function | Torque/speed control mode switching, multi-function input/output terminal, undervoltage regulation, three-ground switching, torque limit, multi-speed operation, slip compensation, PID adjustment, simple PLC, current limit control, manual/automatic torque Lift, current limit, AVR function |
Frequency setting | Operation panel setting, terminal Up/Dn setting, PC setting, analog setting AI1 |
Output frequency | 0.00~3000.0Hz |
Starting frequency | 0.00~60.00Hz |
Acceleration time | 0.01~3600.0s |
Energy consumption braking capability | 400V voltage class inverter: braking unit operating voltage: 650 ~ 750V; 200V voltage class inverter: braking unit operating voltage: 360 ~ 390V; |
DC braking capability | DC braking start frequency: 0.00 ~ 300.0Hz; DC braking current: 0.0~100.0%; No need for DC braking start waiting time for fast braking. |
Flux braking function | The motor can be quickly decelerated by increasing the magnetic flux of the motor |
special function | Multi-function MFK button | The original multi-function button can be used to set frequently used operations: JOG, forward and reverse switching, running command setting mode switching, etc. |
Parameter copy | Parameter uploading and downloading; you can choose to prohibit uploading overlays for parameters that have already been uploaded. |
Models
Model | Input voltage/V | Power /KW | Input current/A | Output current /A | Motor /KW | Unit brake |
C10-0R7G-2SB | Single phase 220~240 | 0.75 | 8.2 | 4.5 | 0.75 | Built-in |
C10-1R5G-2SB | 1.5 | 14.2 | 7.0 | 1.5 |
C10-2R2G-2SB | 2.2 | 23.0 | 10 | 2.2 |
C10-0R7G-2TB | 3 Phase 220~240 | 0.75 | 5.0 | 4.5 | 0.75 |
C10-1R5G-2TB | 1.5 | 7.7 | 7.0 | 1.5 |
C10-2R2G-2TB | 2.2 | 11 | 10 | 2.2 |
C10-0R7G-4TB | 3 Phase 380~480 | 0.75 | 3.4 | 2.5 | 0.75 |
C10-1R5G-4TB | 1.5 | 5.0 | 3.7 | 1.5 |
C10-2R2G-4TB | 2.2 | 5.8 | 5 | 2.2 |
C10-004G-4TB | 4.0 | 10 | 9 | 4.0 |